The converter drainback check valve is located in the cooler outlet (pressure) line near the radiator tank. The valve prevents fluid drainback when the vehicle is parked for lengthy periods. The valve check ball is spring loaded and has an opening pressure of approximately 2 psi.

The valve is serviced as an assembly; it is not repairable.

Do not clean the valve if restricted, or contaminated by sludge, or debris. If the valve fails, or if a transmission malfunction occurs that generates significant amounts of sludge and/or clutch particles and metal shavings, the valve must be replaced.

The valve must be removed whenever the cooler and lines are reverse flushed. The valve can be flow tested when necessary. The procedure is exactly the same as for flow testing a cooler.

If the valve is restricted, installed backwards, or in the wrong line, it will cause an overheating condition and possible transmission failure.

CAUTION: The drainback valve is a one-way flow device. It must be properly oriented in terms of flow direction for the cooler to function properly. The valve must be installed in the pressure line. Otherwise flow will be blocked and would cause an overheating condition and eventual transmission failure.

    More about «Service procedures»:

    Fluid level check

    Fluid and filter replacement

    Transmission fill procedure

    Converter drainback check valve service

    Oil pump volume check

    Flushing coolers and tubes

    Aluminum thread repair

    Jeep Cherokee Service Manual / Transmission and transfer case / Automatic transmission-30RH / Service procedures / Converter drainback check valve service

    Jeep Cherokee Service Manual

    Categories


    © 2017-2024 Copyright www.jcherokee.com