Jeep Cherokee (XJ): Removal and installation

Previous pageService procedures

Refrigerant oil level When an air conditioning system is assembled at the factory, all components except the compressor are refrigerant oil free. After the refrigerant system has been charged and o ...

Next pageService warnings and precautions

WARNING:  THE AIR CONDITIONING SYSTEM CONTAINS REFRIGERANT UNDER HIGH PRESSURE. SEVERE PERSONAL INJURY MAY RESULT FROM IMPROPER SERVICE PROCEDURES. REPAIRS SHOULD ONLY BE PERFORMED BY ...

Other materials:

Accumulator. Blend-air door motor. Blower motor
Accumulator WARNING: REVIEW THE WARNINGS AND CAUTIONS IN THE FRONT OF THIS GROUP BEFORE PERFORMING THE FOLLOWING OPERATION. REMOVAL (1) Disconnect and isolate the battery negative cable. (2) Recover the refrigerant from the refrigerant system. See Refrigerant Recovery in this group for the ...